Firetox Flame Retardant Cables | |||
Firetox Flame Retardant Cables
LSZH Flame Retardant RS 485 Databus Cables
APPLICATION
The cables are designed for RS 485 data connections where continued functionality is required during a fire
situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide
high speed, interference free, data transmission where continued functionality is required during a fire situation.
STANDARDS
Basic design adapted to EIA/TIA 485
FIRE PERFORMANCE
Flame Retardance (Single vertical wire or cable test) | IEC 60332-1-2; EN 60332-1-2 |
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) |
IEC 60332-3-24; EN 60332-3-24 |
Halogen Free |
IEC 60754-1; EN 50267-2-1 |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2 |
Minimum Smoke Emission |
IEC 61034-2; EN 61034-2 |
CABLE CONSTRUCTION
MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE
Conductors : Tinned copper wire, stranded according to IEC 60228 class 2.
Insulation : Foam PE or foam skin PE.
Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two
pair cable had four cores laid in quad formation.
Cabling : Pairs are cabled together in concentric layers.
Overall Screen : Aluminum/polyester tape with tinned copper drain wire.
Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound
type SW2-SW4 as per BS 7655-2.6 can be offered).
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite
properties can be offered as option.
MULTIPAIR RS 485 OVERALL DOUBLE SCREENED DATABUS CABLE
Conductors : Tinned copper wire, stranded according to IEC 60228 class 2.
Insulation : Foam PE or foam skin PE.
Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two
pair cable had four cores laid in quad formation.
Cabling : Pairs are cabled together in concentric layers.
Overall Screen : Aluminium/polyester tape+copper wire braid.
Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound
type SW2-SW4 as per BS 7655-2.6 can be offered).
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite
properties can be offered as option.
MULTIPAIR RS 485 INDIVIDUAL & OVERALL SCREENED DATABUS CABLE
Conductors : Tinned copper wire, stranded according to IEC 60228 class 2.
Insulation : Foam PE or foam skin PE.
Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two
pair cable had four cores laid in quad formation.
Cabling : Pairs are cabled together in concentric layers.
Individual Screen : Individual aluminium/polyester tape.
Overall Screen : Copper wire braid.
Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound
type SW2-SW4 as per BS 7655-2.6 can be offered).
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite
properties can be offered as option.
MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE
Conductors : Tinned copper wire, stranded according to IEC 60228 class 2.
Insulation : Foam PE or foam skin PE.
Cabling Elements : Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two
pair cable had four cores laid in quad formation.
Cabling : Pairs are cabled together in concentric layers.
Overall Screen : Copper wire braid.
Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound
type SW2-SW4 as per BS 7655-2.6 can be offered).
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite
properties can be offered as option.
PHYSICAL AND THERMAL PROPERTIES
Temperature range during operation (fixed state) : -20°C - +90°C
Temperature range during installation (mobile state) : -5°C - +60°C
Minimum bending radius : 8 x Overall Diameter
ELECTRICAL PROPERTIES
Dielectric test | 1000 V r.m.s. for 5’ (core-core) |
1000 V r.m.s. for 5’ (core-screen) |
|
Impedance |
120Ω |
Capacitance |
45 nF/km conductor to conductor |
90 nF/km conductor to shield |
CONSTRUCTION PARAMETERS
Multipair RS 485 Overall Screened Databus Cable
RE-02Y(St)H / RE-02YS(St)H
No.of Pair | Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
No. |
mm² |
No/mm |
mm |
mm |
mm |
kg/km |
1 |
0.22 |
7/0.2 |
0.7 |
1.1 |
5.7 |
45 |
2 |
0.22 |
7/0.2 |
0.7 |
1.1 |
9.0 |
80 |
4 |
0.22 |
7/0.2 |
0.7 |
1.1 |
10.3 |
112 |
1 |
0.50 |
16/0.2 |
0.7 |
1.1 |
6.2 |
57 |
2 |
0.50 |
16/0.2 |
0.7 |
1.1 |
10.1 |
103 |
4 |
0.50 |
16/0.2 |
0.7 |
1.1 |
11.7 |
153 |
1 |
0.75 |
24/0.2 |
0.7 |
1.1 |
6.7 |
66 |
2 |
0.75 |
24/0.2 |
0.7 |
1.1 |
10.9 |
123 |
4 |
0.75 |
24/0.2 |
0.7 |
1.1 |
12.7 |
187 |
1 |
1.00 |
30/0.2 |
0.7 |
1.1 |
6.8 |
72 |
2 |
1.00 |
30/0.2 |
0.7 |
1.1 |
11.2 |
131 |
4 |
1.00 |
30/0.2 |
0.7 |
1.1 |
13.0 |
203 |
Multipair RS 485 Overall Double Screened Databus Cable
RE-02Y(St)CH / RE-02YS(St)CH
No.of Pair | Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
No. |
mm² |
No/mm |
mm |
mm |
mm |
kg/km |
1 |
0.22 |
7/0.2 |
0.7 |
1.1 |
6.2 |
60 |
2 |
0.22 |
7/0.2 |
0.7 |
1.1 |
9.4 |
105 |
4 |
0.22 |
7/0.2 |
0.7 |
1.1 |
10.8 |
142 |
1 |
0.50 |
16/0.2 |
0.7 |
1.1 |
6.7 |
74 |
2 |
0.50 |
16/0.2 |
0.7 |
1.1 |
10.6 |
133 |
4 |
0.50 |
16/0.2 |
0.7 |
1.1 |
12.1 |
187 |
1 |
0.75 |
24/0.2 |
0.7 |
1.1 |
7.1 |
85 |
2 |
0.75 |
24/0.2 |
0.7 |
1.1 |
11.4 |
155 |
4 |
0.75 |
24/0.2 |
0.7 |
1.1 |
13.2 |
225 |
1 |
1.00 |
30/0.2 |
0.7 |
1.1 |
7.3 |
91 |
2 |
1.00 |
30/0.2 |
0.7 |
1.1 |
11.7 |
164 |
4 |
1.00 |
30/0.2 |
0.7 |
1.1 |
13.5 |
242 |
Multipair RS 485 Individual & Overall Screened Databus Cable
RE-02Y(St)CH PiMF / RE-02YS(St)CH PiMF
No.of Pair | Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
No. |
mm² |
No/mm |
mm |
mm |
mm |
kg/km |
1 |
0.22 |
7/0.2 |
0.7 |
1.1 |
6.4 |
61 |
2 |
0.22 |
7/0.2 |
0.7 |
1.1 |
10.2 |
110 |
4 |
0.22 |
7/0.2 |
0.7 |
1.1 |
11.7 |
149 |
1 |
0.50 |
16/0.2 |
0.7 |
1.1 |
7.0 |
75 |
2 |
0.50 |
16/0.2 |
0.7 |
1.1 |
11.4 |
137 |
4 |
0.50 |
16/0.2 |
0.7 |
1.1 |
13.2 |
195 |
1 |
0.75 |
24/0.2 |
0.7 |
1.1 |
7.5 |
86 |
2 |
0.75 |
24/0.2 |
0.7 |
1.1 |
12.3 |
160 |
4 |
0.75 |
24/0.2 |
0.7 |
1.1 |
14.3 |
233 |
1 |
1.00 |
30/0.2 |
0.7 |
1.1 |
7.6 |
92 |
2 |
1.00 |
30/0.2 |
0.7 |
1.1 |
12.6 |
169 |
4 |
1.00 |
30/0.2 |
0.7 |
1.1 |
14.7 |
251 |
Multipair RS 485 Overall Screened Databus Cable
RE-02YCH / RE-02YSCH
No.of Pair | Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
No. |
mm² |
No/mm |
mm |
mm |
mm |
kg/km |
1 |
0.22 |
7/0.2 |
0.7 |
1.1 |
6.0 |
56 |
2 |
0.22 |
7/0.2 |
0.7 |
1.1 |
9.2 |
99 |
4 |
0.22 |
7/0.2 |
0.7 |
1.1 |
10.6 |
134 |
1 |
0.50 |
16/0.2 |
0.7 |
1.1 |
6.5 |
69 |
2 |
0.50 |
16/0.2 |
0.7 |
1.1 |
10.4 |
125 |
4 |
0.50 |
16/0.2 |
0.7 |
1.1 |
12.0 |
179 |
1 |
0.75 |
24/0.2 |
0.7 |
1.1 |
6.9 |
80 |
2 |
0.75 |
24/0.2 |
0.7 |
1.1 |
11.2 |
147 |
4 |
0.75 |
24/0.2 |
0.7 |
1.1 |
13.0 |
216 |
1 |
1.00 |
30/0.2 |
0.7 |
1.1 |
7.1 |
86 |
2 |
1.00 |
30/0.2 |
0.7 |
1.1 |
11.5 |
156 |
4 |
1.00 |
30/0.2 |
0.7 |
1.1 |
13.3 |
233 |